PIR Dual Relay Motion Switch Sensor with Secured Ground Wire Required
The passive infrared sensors work by detecting the difference between heat emitted from the human body in motion and the background space. The sensor switch can turn a load on and hold it as long as the sensor detects occupancy. After no motion is detected for the set time delay, the load turned off automatically. DWOS-JD has two relays (equal to Dual Load Switch), also includes Ambient Light Level Sensor.
DWOS-JD | |
Electrical Specifications | |
Voltage | 120/277VAC, 60Hz |
Fluorescent/Ballast | 800VA@120VAC / 1600VA@277VAC |
Motor | 1/4Hp |
Incandescent | 800W |
Time Delay | 15 Sec to 30 Mins |
Light Level | 30 Lux-Daylight |
Load | Dual Load |
Coverage | |
Coverage | 180°, 1200ft2 |
Environment Specifications | |
Operating Temperature | 32℉-131℉ |
Material Specifications | |
Material | PC |
Standards & Certifications | |
Certification/Listing | UL |
Warranty | 2 Year Limited |
Dual Relays:Control two separate loads, bi-level wiring with VAC and OCC mode
FEATURES:
. OCC/VAC modes available
. Adjustable time delay 15 seconds to 30 minutes
. No neutral wire required(secure ground required)
. Single Pole feed& Single output
. Zero crossing function
. Compatible with all kinds of load including electronic ballast
. CA Title 24
Typical Applications:
. Bedrooms
. Bathrooms
. Laundry Rooms
. Closets
. Garages
. Kitchens
. Home Offices
DIMENTION:
COVERAGE:
The coverage range of the sensor switch is specified and illustrated in Figure 1. Large objects and some transparent barriers like glass windows will obstruct the sensors'view and prevent detection,causing the light to turn off eventhough someone is still in the detection area.
Figure 1
WIRING:
1. Connect lead wires as WIRING DIAGRAM: Black lead to Line 1 (Hot), Blue lead to Line 2 (Hot), Red lead to Primary Load wire, Brown lead to Secondary Load, Green lead to Ground.
ADJUSTMENT:
Mode | Position | Description | React to the push-buttion |
OCCD | Left | Occupancy Mode : Dual load Automatically on,automatically OFF after set time delay both loads together | Manually toggles ON/OFF the loads |
OCCS | Center | Pirmary load Occupancy Mode : Automatic ON. Automatic OFF after set time delay. Secondary load. VAC Mode:Secondary load manual ON Automati OFF after set time delay | Manually toggles ON/OFF the loads |
VACD | Right | Vacancy Mode : Manual ON only, Automatic OFF after set time delay | Manually toggles ON/OFF the loads |
Q1.Are you factory?
A2.YES, Welcome to visit our company and factory.
Q2.What is the warranty?
A2.At least1 year warranty.
Q3.What is the shipping way?
A3.DHL,UPS,TNT,EMS,FedEx.By sea
Q4.What is the payment terms?
A4.T/T
Q5.Can we design customer packing?
A5.YES.We can customer's own packing.
Q6.Can we add our own logo on products?
A6.YES.you can add your logo on them.